AAC(All Aluminum Conductor)

AAC all Aluminum conductor bare conductor is mainly suitable for overhead transmission line .

  • Product Details
  • FAQ
  • Reviews



Application

AAC used in overhead electric power transmission and distribution lines with various grade voltages. Mainly used in urban areas for electricity transfer where the spacing is short and the supports are closer together. Apart from that, these conductors are also extensively used in coastal area because of their corrosion resistance properties.


Standard

IEC 61089, ASTM B231,BS 215 Part 1, EN 50182, DIN 48201 Part 5 etc.


Construction

* Aluminum 1350-H19 wires, concentrically stranded.

*Conductor: Hard drawn aluminium conductor as per EN 60889 Type AL1 according to BS 215 

*The most commonly used stranding consists of 7, 19, 37, 61 and 91 wires.

Bare concentric-lay-stranded aluminum wires constructed with a straight round central aluminum wire surrounded by one or more layers of helically laid aluminum wires. 

*In all constructions, the successive layers shall have opposite directions of lay, the outermost layer being right-handed.


Technical data

IEC 1089 Standard


Area mm2Number of wiresDiameterLinearMass kg/kmRated Strength kND.C Resistance Ω /km
Wire mmConductor mm
1071.354.0527.41.952.8633
1671.715.1243.83.041.7896
2572.136.468.44.51.1453
4072.78.09109.46.80.7158
6373.3910.2172.310.390.4545
100192.5912.9274.8170.2877
125192.8914.5343.621.250.2302
160193.2716.4439.826.40.1798
200193.6618.3549.7320.1439
250194.0920.5687.1400.1151
315373.2923867.951.970.0916
400373.71261102640.0721
450373.9427.51239.8720.0641
500374.15291377.6800.0577
560374.3930.71542.989.60.0515
630613.6332.61738.3100.80.0458


ASTM - B 230 &ASTM - B 231 Standard


Code WordSize (AWG Or Kcmil)StrandingDiameterCross-Sectional Area (Sq. Ins.)Weight Per 1000 Ft. (Lbs.)Rated Strength (Lbs.)Allowable Ampacity
  No. Of WiresClassIndividual Wires Complete Cable    
Peachbell67A0.06120.1840.020625563103
Rose47A0.07720.2320.032839881138
Iris27AA,A0.09740.2920.0522621350185
Pansy17AA0.10930.3280.0657781640214
Poppy1/07AA,A0.12280.3680.0829991990247
Aster2/07AA,A0.13790.4140.10451252510286
Phlox3/07AA,A0.15480.4640.13171573040331
Oxlip4/07AA,A0.17390.5220.16631983830383
Sneezewort2507AA0.1890.5670.19642344520425
Valerian25019A0.11470.5740.19632344660426
Daisy266.87AA0.19520.5860.20952504830443
Laurel266.819A0.11850.5920.20952504970444
Peony30019A0.12570.6280.23582815480478


BS 215 Standard


CODENominal Aluminum AreaStranding: No.and Nominal Diameter of WiresApprox Overall DiameterCalculated D.C Resistance at 20°C (Max)Approx Weight of ConductorBreaking LoadStandard Packing LengthDrum SizeApprox Cross Weight
 SqmmNo./mmmmohm/KmKg/KmKNMetre ± 10% KG
MIDGE227/2.066.181.227643.992000D-7175
ANT507/3.109.30.54191458.282000D-9350
FLY607/3.4010.20.45051749.92000D-9410
WASP1007/4.3913.170.2702290162000D-11680
HORNET15019/3.2516.250.182543425.72000D-141020
CHAFER20019/3.7818.90.134958732.42000D-161380
COCKROACH25019/4.2221.10.108373140.42000D-181700
BUTTERFLY30019/4.6523.250.0891688848.752000D-182020
CENTIPEDE40037/3.7826.460.064114563.12000D-192610


DIN48201 Standard


Conductor AreaNominal Aluminum Area91/2.96Approx Overall DiameterCalculated D.C Resistance at 20°C(Max)Approx Weight of ConductorBreaking LoadStandard Packing LengthDrum SizeApprox Cross Weight
SqmmSqmmNo./mmmmohm/KmKg/KmKNMetre±10% KG
1615.897/1.705.11.8017442.842000D-7130
2524.257/2.106.31.1806674.172000D-8180
3534.467/2.507.50.8332945.742000D-8240
5049.487/3.0090.57861357.952000D-9330
5048.3619/1.8090.59481338.442000D-9330
7065.8219/2.1010.50.43718111.282000D-10425
9593.2719/2.5012.50.308425615.652000D-12625
12011719/2.80140.245932218.742000D-12755
150147.137/2.2515.70.19640625.212000D-14965
185181.637/2.5017.50.155850130.462000D-161210
240242.561/2.2520.20.119267039.392000D-181580


Advantages

High Current Carrying Capacity

excellent resistance to corrosion

Ideal for use in coastal area

suitable for low & medium voltage lines in urban area