Languages

BS 5308 RE-2X(St)HSWAH Armored Instrument Cable

armored instrument cable, XLPE insulation, Aluminium/Polyester Tape screen, LSOH Sheath, tinned copper screen instrument cable,LSOH cable

  • Product Details
  • FAQ
  • Reviews

Application

BS 5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemical industry. The signals can be of analogue, data or voice types and from a variety of transducers such as pressure, proximity or microphone. Part 1 Type 2 cables are designed where a greater degree of mechanical protection is required or where there is direct burial at a

suitable depth. Collectively and individually screened pairs are available within the range. 


Standard

BS/PAS 5308, BS EN 60228, BS 6234, BS EN 50363, BS EN/IEC 60332-1, BS EN/IEC 60332-3-24.


Construction

Conductor: Annealed or tinned copper, sizes: 0.5mm^2 and 0.75mm^2 mulitistranded(Class 5), 0.5 mm^2, 1.0 mm^2 solid(Class 1), 1.5mm^2 or 2.5mm^2 multistranded(Class 2) to BS6360

Insulation: XLPE (Cross Linked Polyethylene), or PE (optional)

Pairing: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm

Colour code: See technical information

Binder tape: PETP transparent tape

Collective screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm^2

Inner Sheath: LSOH(Low Smoke Zero Halogen) sheath

Amour: Galvanized steel wire armour

Outer sheath: LSOH(Low Smoke Zero Halogen) sheath Flame retardant to IEC60332-3-22 Halogen free to IEC60754-1 Low smoke emission to IEC61034-1-2

Sheath colour: Black or blue


Technical data

Operating temperature-20C up to + 90C( fixed installation)

                    0C to +50C(during operation )

Minimum bending radius6 x overall diameter

Special version upon request

Unarmored cable  PVC sheath


Advantages

Reduce toxic smoke and fume emission


Dimensions and Weights



No.of PairsNo.and Dia. of WiresNominal Conductor Cross-Sectional AreaNominal Thickness of InsulationNominal Thickness of beddingNominal Dia. over BeddingNominal Thickness of ArmourNominal Thickness of SheathNominal Dia. of CableApprox. Weight
no./mmmm²mmmmmmmmmmmmkg/km
11/0.800.50.50.85.50.91.39.9200
21/0.800.50.50.86.80.91.311.2260
51/0.800.50.51.110.90.91.415.5460
101/0.800.50.51.214.41.251.620.1790
151/0.800.50.51.216.51.251.622.21100
201/0.800.50.51.318.81.61.725.41280
301/0.800.50.51.322.31.61.829.11520
501/0.800.50.51.528.51.6235.72100
116/0.20.50.60.86.20.91.310.6250
216/0.20.50.60.87.60.91.312300
516/0.20.50.61.112.40.91.517.2560
1016/0.20.50.61.216.51.251.622.2970
1516/0.20.50.61.319.21.61.725.81240
2016/0.20.50.61.321.71.61.828.51640
3016/0.20.50.61.526.41.61.933.41770
5016/0.20.50.61.733.422.141.62770
124/0.20.750.60.86.70.91.410.9280
224/0.20.750.60.98.40.91.412.8330
524/0.20.750.61.213.81.251.619.3750
1024/0.20.750.61.318.41.61.824.31260
1524/0.20.750.61.321.11.61.9271480
2024/0.20.750.61.524.41.6231.41890
3024/0.20.750.61.729.522.1372440
5024/0.20.750.6237.62.52.447.33210
11/1.1310.60.86.60.91.311290
21/1.1310.60.880.91.412.6345
51/1.1310.61.213.51.251.519790
101/1.1310.61.217.71.251.723.61310
151/1.1310.61.320.61.61.827.41740
201/1.1310.61.523.81.61.830.62040
301/1.1310.61.528.41.6235.62180
501/1.1310.6236.622.2453500
17/0.531.50.60.87.50.91.411.9320
27/0.531.50.60.99.30.91.514.1420
57/0.531.50.61.215.61.251.621.6940
107/0.531.50.61.320.91.61.827.41500
157/0.531.50.61.524.61.61.931.21970
207/0.531.50.61.527.81.6235.82400
307/0.531.50.61.733.722.242.33170
507/0.531.50.62432.52.553.25020



Electrical specifications



Conductor Area Sizemm^20.50.50.7511.5
Conductor StrandingNo. x mm1 x 0.816 x 0.224 x 0.21 x 1.137 x 0.53
Conductor resistance maxohm/km36.839.726.518.212.3
Insulation resistance minGohm/km55555
Capacitance unbalance at 1 kHz(pair to pair screen)pF/250m250
Max. Mutual Capacitance @ 1 kHz forNon OS or OS cables (except one-pair and two-pairs)pF/m115115115115120
Max. Mutual Capacitance @ 1 kHz IS/OS cables (include 1 pair and 2 pair)pF/m7575757585
Max. L/R Ratio for adjacent cores(Inductance/ Resistance)μH/ohm2525252540
Test voltageCore to coreV10001000100010001000
Core to screenV10001000100010001000
Rated voltage maxV300/500300/500300/500300/500300/500