Languages

H01N2 Rubber welding cable

H01N2,welding cable,rubber cable,Rubber insulated welding cable,BS EN 50525-2-81 welding cable

  • Product Details
  • FAQ
  • Reviews

Application

These cables are used as a connection to welding robots in the

automotive industry, shipyards and for manually/automatically

operated lines and spot welding. The robust cable structure

makes them resistant to low and high temperatures, ozone and

radiation, oils, acids, fats and petrols.


Standard

BS EN 50525-2-81


Construction

Conductor: Generally to Class 6 flexible copper conductor according to BS EN 60228 (previously BS 6360) 

Separator: PET (Polyester Tape) 

Sheath: Rubber compound, Type EM5 according to BS EN 50363


Technical data

Operating voltage:100 V

Operation temperature:–40°C to + 85°C

Bending radius: 6 x overall diameter


Special version upon request

Color codes

RD-RED color codes

E-Black color codes


Advantages

resistant to low and high temperatures, ozone and radiation, oils, acids, fats and petrols.


Dimensions and Weights(H01N2-D)


No. of coresNominal cross section areaNominal thickness of insulationNominal overall diameterNominal weight
mm²mmmmkg/km
11029146
116210204
125211.5290
135212.5384
1502.214.5535
1702.416.5716
1952.618.5943
11202.820.51235
11503231556


Electrical specifications


ConstructionConductor resistanceCurrent Carrying CapacityOperating capacity 
 20℃CURRENT RATING FOR SINGLE CYCLE OPERATION OVER A MAXIMUM PERIOD OF 5 MINUTES(Amps)
No.xmm2Ω/km100%85%60%
10≤1.91100103108
16≤1.21135145175
25≤0.78180195230
35≤0.554225245290
50≤0.386285305365
70≤0.272355385460
95≤0.206430470560
120≤0.161500540650
150≤0.129580630750